Journal of Membrane Science and Research

Journal of Membrane Science and Research

Separation Performance of Improved PERVAPTM Membrane and Its Dependence on Operating Conditions

Document Type : Research Paper

Author
DeltaMem AG, 4132-Muttenz, Switzerland
Abstract
By using binary ethanol/water mixtures, the separation performance of two improved commercial pervaporation embranes (PERVAPTM) are presented. Separation performance data are analyzed and compared as a function of operating conditions. The effect of initial feed concentration on the separation performance and the effect of feed concentration on apparent activation energy are presented. For membranes that swell, we show that permeance values and selectivity are also dependent on operating conditions. In addition, the results show the importance of initial feed concentration in pervaporation tests. Arbitrary initial feed concentrations lead to different separation performance. Nevertheless, this membrane feature can be used for tuning the final separation performance.

Graphical Abstract

Separation Performance of Improved PERVAPTM Membrane and Its Dependence on Operating Conditions
Keywords
Subjects

Volume 5, Issue 3
Summer 2019
Pages 216-221

  • Receive Date 14 June 2018
  • Revise Date 17 August 2018
  • Accept Date 18 August 2018